RPs, double checks, PVBs, SVBs and fire line assemblies each get their own test steps. We know them all. The price goes by size, not type, so it's still $105 under 4 inches.
Easiest way? Just call.
- Price$105 flat
- TimeUnder an hour
- SchedulingSame week
- FilingIncluded
Pricing
| Backflow size | Flat fee per backflow |
|---|---|
| Under 4" | $105 |
| 4" and larger | $175 |
Includes the test and filing with your water district. No hidden fees.
Devices we test
- Detector assemblies on fire sprinkler services
- PVBs and SVBs on irrigation
- RP assemblies on commercial and high-hazard lines
- Double checks on fire lines and lower-hazard services
How we test an RP or RPZ
RP assemblies, sometimes written RPZ, protect connections where the risk is highest: chemical feeds, medical equipment, boilers, car washes and similar uses. Inside are two check valves and a relief valve in the middle that opens to the air if pressure between the checks gets too close to the supply pressure.
When we test an RP, we measure when that relief valve opens and whether each check valve holds. Those readings go on the report your district reviews.
A dripping or spitting relief valve between tests usually means debris or wear on the first check. We note it on the visit and explain whether it needs attention now. Catching it early tends to be cheaper than waiting for a failed test or a valve that won't stop discharging.
How a double check is tested
A double check valve assembly has two independent check valves in a row and no relief valve. It's approved for lower-hazard connections, like many fire sprinkler systems and some irrigation and domestic lines.
The test confirms that each check valve holds pressure in the direction it's supposed to. The tester isolates each check in turn using the shutoff valves and test cocks, then reads the gauge.
Double checks are often installed below ground in vaults or boxes, especially on fire lines. That can make access the hardest part of the job. If your device sits in a vault that fills with water or dirt, let us know when you book so we come ready to pump it out before the test.
Testing PVBs and SVBs
PVBs and SVBs are common on residential and commercial irrigation. They're the above-ground devices with a bonnet on top, usually near the sprinkler valves. Their job is to stop water from being siphoned back out of the sprinkler lines when pressure drops on the supply side.
The test checks two things: that the air inlet opens and that the check valve holds tight. It's quick, and these are often the easiest devices to reach.
Placement matters with these. They need to be above the highest downstream sprinkler or outlet to work as designed. If yours looks too low, we'll tell you, because a device can pass its readings and still be installed wrong.
Testing devices on fire sprinkler services
Many commercial and multi-unit buildings have a double check detector assembly (DCDA) or a reduced pressure detector assembly (RPDA) on the fire sprinkler line. These have a small bypass with a meter that shows if water is being used on the fire line when it shouldn't be.
We test the main assembly and the bypass assembly, since both protect the water supply. Fire line devices are often 4 inches or larger, which falls in the $175 per device price tier.
Fire systems usually involve more than one party: the building owner, the fire sprinkler contractor and sometimes the fire department. Closing valves on a fire line can trigger alarms, so we coordinate with you first and follow the steps needed to keep the system covered.
Identifying your device
The type is usually printed on the device or a tag attached to it. Without a label, look at the shape. RPs have a relief port underneath between two checks. Double checks have two check covers and no relief port. PVBs and SVBs have a bonnet on top.
There's no need to figure it out yourself. Send a photo when you book, or let the tester identify it when they arrive.
How age affects results
Condition counts more than type. A well-maintained older device often passes without trouble, and a newer one on a dirty line can fail.
Age still plays a part, since rubber and springs wear out over time. When a device gets old enough that parts are hard to source, we'll tell you so you can plan a replacement on your schedule instead of in a hurry.
Not sure what's installed?
See how to tell RP, double check and PVB apart, or just send us a photo.
Questions
Do fire line devices need the fire department?
Usually not for the test itself, but we coordinate with you first since closing valves can trigger alarms.
Is an RPZ the same as an RP?
Yes. Both names refer to a reduced pressure principle assembly.
Do all types cost the same to test?
Pricing goes by size, not type: $105 for devices under 4 inches and $175 for 4 inches and up.
Which type is most common on homes?
On sprinkler lines it's usually a PVB or double check. On the main line it's often a double check or RP.
Can you test a device installed underground?
Yes. Let us know when you book if the vault fills with water or dirt so we come ready to clear it.
Is the price different for an RP?
No. We charge by size: $105 under 4 inches, $175 for 4 inches and larger.
Why folks in Chula Vista call us
Backflow is what we do. Our testers are certified, our gauges are calibrated, and we send the report to your water district for you, every time.
No surprises on price: $105 for devices under 4 inches, $175 for 4 inches and up, and free quotes on everything else. We answer seven days a week, 6am to midnight, and emergencies around the clock.
Here's how a visit goes. We call or text when we're on the way, find the device, and get the test done. If it passes, that's it: we file the report and send you a copy. If it doesn't, we'll show you what's wrong, tell you the price and fix it if you want us to. Most folks around Chula Vista never need to be home for any of it.
Chula Vista and nearby
We do backflow preventer testing in Chula Vista, National City, Paradise Hills, Bonita, Imperial Beach and Encanto. We can usually come out this week.