Leaks, missing caps, cracks, a box that floods, a device that's too low. We check for all of it whenever we test and tell you what's worth fixing now and what can wait.
Easiest way? Just call.
- Price$105 flat
- TimeUnder an hour
- SchedulingSame week
- FilingIncluded
What an inspection covers
- Drainage under RP relief valves
- Shutoff valves and test cocks
- Clearance and access for testing
- Leaks, cracks and corrosion
- Freeze and theft protection
Inspection and testing are different things
A backflow test answers one question: do the valves hold when measured with a gauge? An inspection answers a wider one: is this device in good condition and installed in a way that lets it keep working and be tested every year?
A device can pass its readings and still have problems. It might be leaking from a fitting, missing a test cock cap, sitting in a pit where an RP isn't allowed, or wedged so tightly against a wall that the next tester can't reach it. Those issues don't show up in the numbers.
That's why we look over the device and its surroundings on every visit. Anything worth knowing gets noted, along with whether it needs attention now or can wait.
Installation problems we often find
A lot of issues trace back to the original install. RPs need to sit above grade so the relief valve can dump water freely. If one is in a vault or a box that fills with water, it can't do its job.
PVBs and SVBs have to be higher than the sprinklers they protect. Hillside yards make this easy to get wrong, with heads above the device.
Other finds include devices installed in the wrong direction, devices crammed into spaces too tight to test, and shutoff valves that don't seal. All of these are fixable, and we'll walk you through what it would take.
Signs of wear and damage
Wear tends to show before a device fails outright. Mineral crust around joints means small leaks. A relief valve that drips now and then usually means the first check needs cleaning or new rubber. Rusted hardware can turn a simple repair into a bigger one later.
We check for cracks from freezing and dents or bends from mowers, cars and landscaping work. Missing test cock caps let in debris that can affect readings.
Brass theft is also common, especially near streets and parking lots. If yours is exposed, we might recommend a cage. You'll hear which items need attention right away and which can wait.
Times to ask for an inspection
Inspection is part of every test we do, but there are times you might want one by itself. Buyers sometimes ask for it before closing on a property, especially commercial buildings with several devices.
It's also worth a look after a hard freeze, after construction or landscaping work near the device, or after a car or equipment has hit it. Property managers taking over a new building often want to know what they're inheriting.
Call and tell us what's going on. If the device is due for its annual test anyway, we'll usually do both on the same visit so you get a passing report and a full picture of its condition.
Where the water goes
RP assemblies are designed to discharge water from the relief valve when something goes wrong. That water has to go somewhere. If an RP is mounted indoors without a drain, or outdoors where discharge floods a walkway or parking lot, a small problem can cause bigger damage.
We look at where discharge would go and whether the drain or grading can handle it. If not, we'll suggest options like an air gap drain funnel or relocating the device.
How we report what we found
We keep inspection notes brief and clear. For each item, you'll see what we found, why it matters and how urgent it is: now, soon or next year.
Repairs come with prices attached. We don't pad the list, so everything on it deserves a look. Managers frequently forward the notes to owners or boards as-is.
Before you buy a property
Buying a commercial building, apartment complex or home with irrigation, pools or fire sprinklers? Backflow devices are easy to overlook during due diligence, and replacing several can add up.
An inspection before closing tells you how many devices there are, what shape they're in and whether any are the wrong type or due for replacement. That's useful when negotiating repairs or planning your first year's budget.
If something needs work
We'll tell you what we saw and whether it needs a repair or can wait.
Questions
Do you inspect devices you didn't install?
Yes. We inspect every device we test, no matter who put it in.
Can an inspection catch problems before a test fails?
Often, yes. Leaks, worn parts and bad drainage show up before the readings drop.
Will you send me what you found?
Yes. Anything worth noting goes in writing with your report.
Will an inspection fix the problems it finds?
No, but we'll explain each issue and give you a price for any repair.
Is an inspection the same as a test?
No. The test measures how the valves perform. The inspection looks at the device's condition and setup. We do both on every visit.
Does the inspection cost extra?
It's part of every test we do. Call if you need an inspection on its own.
Why folks in Chula Vista call us
Backflow is what we do. Our testers are certified, our gauges are calibrated, and we send the report to your water district for you, every time.
No surprises on price: $105 for devices under 4 inches, $175 for 4 inches and up, and free quotes on everything else. We answer seven days a week, 6am to midnight, and emergencies around the clock.
Here's how a visit goes. We call or text when we're on the way, find the device, and get the test done. If it passes, that's it: we file the report and send you a copy. If it doesn't, we'll show you what's wrong, tell you the price and fix it if you want us to. Most folks around Chula Vista never need to be home for any of it.
Chula Vista and nearby
We do backflow inspection in Chula Vista, National City, Paradise Hills, Bonita, Imperial Beach and Encanto. We can usually come out this week.